Key Features and Technical Specifications:
Conductor: Multistrand flexible plain annealed copper.
Insulation: PVC (Flame Retardant) or FRLSH (Flame Retardant Low Smoke Halogen).
Voltage Grade: Up to 1100 Volts.
Standards: Conforms to IS 694, IS 8130 Class 5, and IS 5831 Type D.
Sizes: Ranging from 0.5 sq. mm to 300 sq. mm.
Core Colors: Red, yellow, blue, black, green, and green/yellow.
Safety Features: Lead-free, 100% conductivity, and flame retardant.
Common Applications:
Residential & Commercial: Wiring for homes, offices, and buildings.
Industrial: Internal wiring for switchboards, control panels, and cabinets.
Engineering: Suitable for machinery and industrial equipment.
Wired and Cable
-
FR (Flame Retardant) insulation 70°C | Hazardous substance free | Does not propagate flame & fir
-
Flexible single core cable with Flame Retardant PVC insulation. This cable can be used in panels, cabinets, machines and internal wirings with switchgears, relays, controllers, equipments, controls units, etc.
-
Approvals: IS 694 marked, FIA/TAC
Cable Code: Y (FR)
Voltage Grade: Up to and including 1100V
Conductor: Flexible electrolytic annealed plain copper, class 5, IS 8130
Insulation: FR (Flame Retardant) PVC, IS 5831
Packing: 200 mtr. In polybag packing up to 4 sq. mm and shrink wrap packing for 6 Sq. mm and above. Product also available in 100 meter packing.
-
FR-LSH (Flame Retardant Low Smoke and Halogen) insulation 70°C | Does not propagate flame & fire | Reduced Smoke and acid gas emission
-
Flexible single core cable with FR-LSH (Flame Retardant Low Smoke and Halogen) PVC insulation. This cable can be used in panels, cabinets, machines and internal wirings with switchgears, relays, controllers, equipments, controls units, etc. specially in hazard prone areas. They also find their usage in flexible wiring installations in industrial and commercial areas with dense population.
-
Approvals: IS 694 marked, FIA/TAC
Cable Code: Y (FR-LSH)
Voltage Grade: Up to and including 1100V
Conductor: Flexible electrolytic annealed plain copper, class 5, IS 8130
Insulation: Specially formulated FR-LSH (Flame Retardant Low Smoke and Halogen) PVC, IS 5831
Packing: 200 mtr. In polybag packing up to 4 Sq. mm Shrink wrap packing for 6 Sq. mm and above
-
HFFR (Halogen Free Flame Retardant) insulation 70°C | Non-Toxic & Non-Corrosive | Does not propagate flame & fire.
-
Flexible single core cable with Halogen Free Flame Retardant insulation. These are suitable for flexible installations preferably in panels, cabinets, machinaries, controllers, equipments used in chemical industries, oil and gas industries, in explosive or fire prone areas where safety is utmost important. They also find their usage in flexible wiring installations in industrial and commercial areas with dense population.
-
Approvals: IS 17048 marked, FIA/TAC
Cable Code: Z
Voltage Grade: Up to and including 1100V
Conductor: Flexible electrolytic annealed plain copper, class 5, IS 8130
Insulation: HFI-TP 70, Thermoplastic halogen free flame retardant.
Packing: 200 meter in polybag packing.
-
Electron Beam Cross-linked | HFFR (Halogen Free Flame Retardant) insulation | Non-Toxic & Non-Corrosive
-
These advanced E-Beam crosslinked halogen-free single-core cables are ideal for flexible installations in panels, cabinets, machinery, controllers and equipment used in chemical industries, oil and gas sectors, and other hazardous or fire-prone environments. They are specifically designed for industrial and commercial applications in densely populated areas, ensuring superior fire safety, low smoke emissions, and high durability.
-
Approvals: IS 17048 marked, FIA/TAC
Cable Code: XZ
Voltage Grade: Up to and including 1100V
Conductor: Flexible electrolytic annealed plain copper, class 5, IS 8130
Insulation: E-Beam Crosslinked HFI-XL 90 Halogen Free Flame Retardant (HFFR)
Packing: 200 meters in polybag packing
-
DIN EN 50525-2-31, VDE 0285-525-2-31, BS EN 50525-2-31.
-
Cable designed for internal wiring in switch control, relay and instrumentation panels of power switchgear and for purposes such as stationary, static appliances, internal connectors in rectifier equipment, motor starters and controllers.
-
Voltage Rating: H05V-K 0.5 to 1 mm² – 300 / 500V, H07V-K 1.5 to 240 mm² – 450 / 750V
Temperature Range: -30°C to +70°C
Minimum Bending Radius :
Cable diameter ≤ 8 mm: 4 x outer diameter
Approx. diameter > 8 to 12 mm: 5 x outer diameter
Approx. diameter > 12 mm: 6 x outer diameter
Test Voltage: 2500V
-
Standard
BS/VDE EN 50525-2-31.
-
Heat resistant cable designed for internal wiring in switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
-
Voltage Rating: H05V2-K 0.5 to 1 mm² – 300 / 500V, H07V2-K 1.5 to 35 mm² – 450 / 750V
Temperature Range: -30°C to +90°C
Minimum Bending Radius :
Cable diameter ≤ 8 mm: 4 x outer diameter
Approx. diameter > 8 to 12 mm: 5 x outer diameter
Approx. diameter > 12 mm: 6 x outer diameter
Test Voltage: 2500V
-
Standard
BS EN 50525-3-41.
-
Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to be protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed installation ducts. The direct operating voltages is permitted up to 900 V against ground when they are used in rail-coaches. For the inner wiring of switch boards and distributors these are to be used with an alternating nominal voltage up to 1000V or a direct voltage up to 750V against ground.
-
Nominal Voltage : H05Z-K Uo / U 300 / 500V, H07Z-K Uo / U 450 / 750V
Harmonised Designation: 0.5 mm² to 1 mm² – H05Z-K, 1.5 mm² to 240 mm² – H07Z-K
Temperature Range: -15°C to +90°C
Minimum Bending Radius :
Cable diameter ≤ 8 mm: 4 x outer diameter
Approx. diameter > 8 to 12 mm: 5 x outer diameter
Approx. diameter > 12 mm: 6 x outer diameter
Test Voltage: 2500V
-
Standard
BS EN 50525-3-31.
-
Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to protected from further damage resulting from fire. These cables may be installed on, in and beneath plaster, as well as in closed installation ducts. For use in public places such as: hospitals, schools, museums, airports, bus terminals, shops in general, etc., as well as in computer rooms, offices, production plants, switchboard wiring, laboratories, etc.
-
Nominal Voltage : H05Z1- K Uo / U 300 / 500V; H07Z1- K Uo / U 450 / 750V
Harmonized Designation : 0.5 mm² to 1 mm² – H05Z1- K, 1.5 mm2 to 240 mm2 – H07Z1- K
Temperature Range : -30°C to +70°C
Minimum Bending Radius :
Cable diameter ≤ 8 mm: 4 x outer diameter
Approx. diameter > 8 to 12 mm: 5 x outer diameter
Approx. diameter > 12 mm: 6 x outer diameter
Test Voltage: 2500V
-
Standard
BS6231 Type CK.
-
High temperature, flame retardant cable designed for use in switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
-
Voltage Rating: 600 / 1000V
Temperature Rating : 90°C (105°C for 15,000 hours)
Minimum Bending Radius :
Cable diameter ≤ 8 mm: 4 x outer diameter.
Approx. diameter > 8 to 12 mm: 5 x outer diameter
Approx. diameter > 12 mm: 6 x outer diameter
Test Voltage: 4000V
-
Annealed plain or tinned stranded copper conductor.
PVC – core insulation according to UL – Standard 1581, Class 43 Tab. 50.182, heat and damp resistant. -
These cables are used for internal wiring of panels and electrical equipment. These are used as connection wire in machines laid in protective tubes and flexible pipes and also for motors and transformers.
-
Standard: UL – Std. 758, CSA C 22.2 No. 210
Nominal Voltage: 600V
UL: type AWM 105°C 600V
CSA: type AWM 105°C 600V
Test Voltage (Spark Test):
AWG 24: 4kV
AWG 22 and 20: 5kV
AWG 18 to 16: 6kV
≥ AWG 8: 7.5kV
Temperature Range: Flexing -5°C to +105°C. Fixed installation -20°C to +105°C
Temperature at Conductor: Max. UL and CSA : +105°C
Bending Radius: Flexing 10 x cable ø’. Fixed installation 5 x cable ø
-
Annealed plain or tinned stranded copper conductor.
PVC – core insulation according to UL – Standard 1581, Class 43 Tab. 50.182, heat and damp resistant. -
These cables are used for internal wiring of switchboards, electronic and electrical equipment, e. g. households, radio of televisions, monitor and control desks.
-
Standard: UL – Std. 758 , CSA C 22.2 No. 210
Nominal Voltage: 300V
Test Voltage: 2000V Test Voltage (Spark Test)
AWG 26-20: 4kV, AWG 10 -18 : 5kV
Temperature Range: Flexible -5°C to +80°C. Fixed installation -20°C to + 80°C CSA – AWM I A/B
Bending Radius: Flexing 10 x cable ø. Fixed installation 5 x cable ø
-
Annealed plain or tinned stranded copper conductor.
PVC – core insulation according to UL – Standard 1581, Class 43 Tab. 50.182, heat and damp resistant. -
These cables are used for internal wiring of switchboards, electronic and electrical equipment, e. g. households, radio of televisions, monitor and control desks.
-
Standard: UL – Std. 758 , CSA C 22.2 No.210
Nominal Voltage: 300V
Test Voltage: 2000V Test Voltage (Spark Test)
AWG 26-20: 4kV, AWG 10 -18: 5kV
Temperature Range: Flexible -5°C to + 105°C. Fixed installation -20°C to + 105°C CSA – AWM I A/B
Bending Radius: Flexing 10 x cable ø. Fixed installation 5 x cable ø
-
Cable Construction
Annealed plain or tinned stranded copper conductor.
PVC – core insulation Type TW, Recognized Component QMTT2 heat and damp resistant. -
PVC-insulated heavy wall lead wire, for use as hook – up wire and for internal wiring on refrigeration equipments.
-
Standard: UL – Std. 758 , CSA C 22.2 No.210
Temperature Range: -20°C to 105°C
Nominal Voltage: 600V
Test Voltage (Spark Test):
AWG 18 to 16 : 6kV
≥ AWG 8: 7.5kV
Bending Radius: Fixed installation 5 x cable ø
-
Annealed plain or tinned stranded copper conductor.
XLPE insulation according to UL- Std. 1581 Table 50.232, Complies to CSA No. 22.2 210 and 127.
-
These cables have excellent resistance to abrasion, deformation, cut-through and chemical attack. This wire is widely used in appliances, transformers, electrical heating, motors, ballast, lighting and cooking equipment. Suitable for use as Appliance Wiring Material (AWM), coil leads and as Class B IEEE 130°C Class Motor Leads. Economical replacement for silicone rubber/glass braid insulated wire and cable.
-
Standard: UL – Std. 758. Complies to CSA No. 22.2 210 and 127
Nominal Voltage: 600V
Test Voltage (Spark Test):
AWG 22 and 20: 5kV
AWG 18 to 10: 6kV
≥ AWG 8: 7.5kV
Temperature Range: Flexible -5°C to +150°C. Fixed installation -50°C to +150°C
Temperature at Conductor: Max. UL : +150°C
Bending Radius: Approx. 5 x cable ø