TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV

$0.00

Flexible LSZH screened cable for Variable Frequency Drive (VFD) cables .

ACCORDING TO: IEC 60502-1., IEC 60092-353.

TOPDRIVE® VFD ROZ1-K cable has been specially designed for VFD Motors and where it is necessary to limit the effects of electromagnetic interference.

  • Screen 100% shielding coverage

  • For VFD applications

  • EMI protection

Flexible LSZH screened cable for Variable Frequency Drive (VFD) cables .

ACCORDING TO: IEC 60502-1., IEC 60092-353.

TOPDRIVE® VFD ROZ1-K cable has been specially designed for VFD Motors and where it is necessary to limit the effects of electromagnetic interference.

  • Screen 100% shielding coverage

  • For VFD applications

  • EMI protection

Application

TOPDRIVE® VFD ROZ1-K cable has been designed for Variable Frequency Drive Motors and installations where it is necessary to limit the effects of electromagnetic interference (EMI). This is a flexible cable for fixed installations, for variable speed motors or pumps.

Characteristics

  • Copper, class 5 (flexible).

    • 1,8/3kV

    • Maximum conductor temperature: 90ºC.

    • Maximum short-circuittemperature: 250ºC (max. 5 s).Maximum ambient temperature: 60 ºC.

    • Minimum installation and handling temperature: 0 °C.

    • Minimum service temperature: -40ºC (fixed and protected installations).

    • Flame non-propagation according to EN 60332-1 / IEC 60332-1.Fire non-propagation according to EN 60332-3 / IEC 60332-3 and EN 50399.

    • Reaction to fire CPR: Cca-s1a, d1, a1 according to EN 50575.LSZH (Low Smoke Zero Halogen) according to IEC 60754-1.

    • Low corrosive gases emission according to EN 60754-2 / IEC 60754-2.Low smoke emission according to EN 61034 / IEC 61034:Light transmittance > 80%.

    • Minimum bending radius during installation: 10x cable diameter.

    • Minimum bending radius, fixed: 10x cable diameter.

    • Impact resistance: AG2 Medium severity.

  • Chemical & Oil resistance: Acceptable.

    UV resistant according to EN 50618.

    Water resistance: AD5 Jets.

  • In conduit.

  • Open Air.

    Buried.

    In conduit.

Typical applications of

TOPDRIVE® VFD ROZ1-K 1,8/3 kV (EMC)

  • TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable is specifically engineered to suppress capacitive leakage currents and dampen reflected wave phenomena, ensuring reliable motor operation and protecting against damaging voltage spikes. A 3+3 configuration in a VFD cable utilizes three main power conductors alongside three symmetrically arranged grounding conductors, which provides a balanced impedance path for common-mode currents to effectively cancel out electromagnetic interference.

  • TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable ensure long-term stability against thermal aging and mechanical stress, guaranteeing sustained performance and reliability over the lifespan of a fixed installation.

  • TOPDRIVE® VFD (EMC) ROZ1-K 0,6/1kV cable is specifically engineered to suppress capacitive leakage currents and dampen reflected wave phenomena, ensuring reliable motor operation and protecting against damaging voltage spikes. A 3+3 configuration in a VFD cable utilizes three main power conductors alongside three symmetrically arranged grounding conductors, which provides a balanced impedance path for common-mode currents to effectively cancel out electromagnetic interference.